Place of Origin: | China |
Brand Name: | Enargy |
Model Number: | SC224-220S28 |
Minimum Order Quantity: | 1pcs |
---|---|
Price: | Negotiation |
Delivery Time: | 1-8 Weeks |
Payment Terms: | Negotiation |
Supply Ability: | 15000Pcs/week |
Highlight: | ac to dc power supply |
---|
AC-DC Power Supplies 224W Output 28V SC224-220S28
Key Features
AC input range: 140~300Vac
Single outputs: 28V/8A
High efficiency: 88%
Line regulation: ≤±3%
Load regulation: ≤±3%
Low ripple&noise: ≤150mV
Power factor: 95%
short circuit protection
Output over current protection
Output over voltage protection
Input over voltage protection
Input under voltage lock-out
AC operation signal
Natural cool
RoHS compliant
UL94V-0 flame-retarded rating
Product Overview
This AC-DC converter use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency switching provides high power density with low noise and high efficiency.
Electric Characteristics
Input Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
Rated input voltage |
200 |
220 |
240 |
Vac |
|
|
AC input voltage range |
140 |
|
300 |
Vac |
|
|
Rated AC input frequency |
|
50/60 |
|
Hz |
|
|
AC input frequency range |
47 |
|
63 |
Hz |
|
|
Max. input current |
|
|
2.5 |
A |
Min. input voltage, full load |
|
Input inrush current |
|
|
30 |
A |
Max. input voltage,25℃, first start |
|
Efficiency |
AC input |
|
88 |
|
% |
Rated input voltage, rated load |
Power factor |
95 |
|
|
% |
|
|
Output Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
Output voltage range |
28V |
27.5 |
28 |
28.5 |
Vdc |
|
Output current range |
28V |
0 |
|
8 |
A |
|
Line Regulation |
|
|
±3 |
% |
|
|
Load Regulation |
|
|
±3 |
% |
|
|
Temperature Regulation |
|
±0.02 |
|
% / °C |
Over operating temperature range |
|
Ripple & noise |
28V |
|
|
150 |
mV |
Rated input, full load, 20 MHz bandwidth |
Dynamic response |
Deviation |
|
|
±5 |
% |
25% to 50% to 25% Iout max, 50% to 75% to 50% Iout max, 1A/us |
Settling time |
|
|
500 |
uS |
||
Turn-on rise time |
|
|
50 |
ms |
Full load,10%~90% Vout |
|
Turn-on delay time |
|
|
8 |
s |
220Vac, Full load |
|
Output voltage overshoot |
|
|
±5 |
% |
|
|
Output Capacitance |
|
|
3000 |
μF |
|
Protection Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
Input under voltage lock out |
Turn-on voltage threshold |
130 |
|
145 |
Vac |
|
Turn-off voltage threshold |
115 |
|
130 |
Vac |
|
|
Input over voltage protection |
Protect voltage |
300 |
|
320 |
Vac |
|
Recovery voltage |
280 |
|
300 |
Vac |
|
|
Output over voltage protection |
32 |
|
35 |
Vdc |
Hiccup |
|
Output over load protection |
9 |
|
12 |
A |
Hiccup |
|
Short – Circuit Protection |
|
|
10 |
mΩ |
Hiccup |
General Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
MTBF |
250 |
|
|
KHrs |
Rated input, full load,25℃ |
Weight |
|
|
1000 |
g |
|
Environmental Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
Operating temperature |
-40 |
|
+85 |
℃ |
|
Storage temperature |
-40 |
|
+85 |
℃ |
|
Relative humidity |
10 |
|
95 |
% |
|
Storage humidity |
105 |
|
93 |
% |
|
Altitude |
|
|
3000 |
m |
|
Atmospheric pressure |
70K |
|
106K |
Pa |
|
Safety Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
Isolation voltage |
Input to output |
1500 |
|
|
Vac |
10mA/1min, No arcing and breakdown |
Input to ground |
1500 |
|
|
Vac |
||
Output to ground |
500 |
|
|
Vdc |
10mA/1min, No arcing and breakdown |
|
Isolation resistance |
Input to output |
10 |
|
|
MΩ |
500Vdc/1min, normal atmospheric pressure, 90% humidity |
Input to ground |
10 |
|
|
|||
Output to ground |
10 |
|
|
Signal and Switch
Item |
Functions |
Notes |
Output under voltage alarm |
Output under voltage alarm turns to logic high(5V±0.2V) when output voltage drop to 90% |
Logic high when abnormal condition, Logic low when operating well |
Input signal |
Light on when operating well, light off when operating abnormal |
Φ3 green light |
Output signal |
Light on when operating well, light off or blink when operating abnormal |
Φ3 green light |
EMC Characteristics
Item |
Standards |
Conditions |
Notes |
|
CE |
EN55022 |
Class B |
Pass system test |
|
RE |
EN55022 |
Class B |
Pass system test |
|
Harmonic |
EN61000-3-2 |
C type lamps requirements |
Criterion B |
|
Voltage fluctuations and flicker |
EN61000-3-3 |
Class A equipments requirements |
Criterion B |
|
Surge |
EN61000-4-5 |
Differential mode ±2KV,common mode±4KV |
Criterion B |
|
DIP |
EN61000-4-11 EN55024 |
Voltage dip to 0%Ut,10ms |
Criterion B, test at phase 0, 90, 180 and 270 |
|
Voltage dip to 40%Ut, 20ms |
||||
Voltage dip to 70%Ut,50ms |
||||
ESD |
Air discharge |
EN61000-4-2 |
±8KV |
Criterion B |
Contact discharge |
EN61000-4-2 |
±4KV |
Criterion B |
Notes:
Criterion A: Normal performance during and after test.
Criterion B: Low-voltage protection or reset is not allowed. Temporary output voltage fluctuation ceases after disturbances ceases, and from which the EUT recovers its normal performance automatically. During the system test, output voltage fluctuation or reset is not allowed too.
Criterion C: Temporary loss of output is allowed, but the hardware can’t be damaged. The EUT recovers its normal performance automatically or operator intervention.
Criterion R: Loss of output which is not recoverable is allowed. The primary protective component (fuse) can be damaged. The EUT recovers its normal performance after replace the damaged component.
Environmental Qualification
Parameter |
Notes |
Vibration |
Frequency range: 5-20Hz,+3dB/otc; 20-80Hz,0.04g2/Hz; 80-500Hz, -3dB/ot c ; X.Y.Z axes, 30min/axis |
Mechanical Shock |
Half-sine wave, 300m/s2,11ms, ±X,±Y,±Z, 6tims/direction |
Standards compliance
Standards |
Notes |
UL/UL60950 |
|
EN60950 |
|
Physical Information
Mechanical Outline
Length×width×heigth:127.0×84.5×35.0(mm), 5×3.33×1.38(inch),
Connector designations
Input connector: VH3.96mm-3PIN
Pin No. |
Name |
Function |
1 |
L |
|
2 |
N |
|
3 |
PE |
|
Output connector: VH3.96mm-6PIN, fast back,
Output wires: UL1015 18#, 105℃, 600V
Pin No. |
Name |
Function |
1 |
+28V |
Red |
2 |
+28V |
Red |
3 |
GND |
Black |
4 |
GND |
Black |
5 |
LOS_PWR+ |
Output under voltage alarm positive (red) |
6 |
LOS_PWR- |
Output under voltage alarm positive (black) |