Input 165~285V Telecom Power Supply 45W Output 9V/2.0A,9V/3.0A,8.8V/0.15A CMA45-220D9
Key Features
AC input range: 165~285Vac
Li battery input range:14.8Vdc
DC input voltage:12V
Triple outputs: 9V/2.0A,9V/3.0A,8.8V/0.15A
High efficiency:75%
Line regulation: ≤±1%
Load regulation: ≤±3%
Low ripple&noise:≤50mV
short circuit protection
Output over current protection
Output over voltage protection
Input over voltage protection
Input under voltage lock-out
AC operation signal
DC operation signal
Soft On/Off function
Seamless switch between AC, battery and DC
Natural cool
RoHS compliant
UL94V-0 flame-retarded rating
Product Overview
This AC-DC converter use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency switching provides high power density with low noise and high efficiency.
Electric Characteristics
Input Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
AC input voltage range |
165 |
|
285 |
Vac |
|
|
AC input turn-on range |
165 |
|
285 |
Vac |
|
|
Rated AC input frequency |
|
50 |
|
Hz |
|
|
AC input frequency range |
45 |
|
65 |
Hz |
|
|
Max. input current |
|
|
2 |
A |
Min. input voltage, full load |
|
Input inrush current |
|
|
45 |
A |
Max. input voltage,25℃, first start |
|
Battery input voltage |
|
9 |
|
Vdc |
|
|
Efficiency |
AC input |
75 |
|
|
% |
Rated input voltage, rated load |
Output Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
Output voltage range |
9Vmoden |
8.75 |
9.00 |
9.25 |
Vdc |
|
9V |
8.75 |
9.00 |
9.25 |
Vdc |
|
|
Battery charging |
|
9 |
|
Vdc |
|
|
Output current range |
9Vmoden |
0.3 |
|
2 |
A |
|
9V |
0.3 |
|
3 |
A |
|
|
Line Regulation |
|
|
±1 |
% |
|
|
Load Regulation |
|
|
±3 |
% |
|
|
Temperature Regulation |
|
±0.02 |
|
% / °C |
Over operating temperature range |
|
Ripple & noise |
9Vmoden |
|
|
50 |
mV |
Rated input, full load, 20 MHz bandwidth |
9V |
|
|
50 |
mV |
Rated input, full load, 20 MHz bandwidth |
|
Dynamic response |
Deviation |
|
|
±7 |
% |
25% to 50% to 25% Iout max, 50% to 75% to 50% Iout max, 0.1A/us |
Settling time |
|
|
500 |
uS |
To within 1% Vout nom. |
|
Turn-on rise time |
|
|
500 |
ms |
Full load,10%~90% Vout |
|
Turn-on delay time |
|
|
5 |
s |
220Vac, Full load |
|
Output voltage overshoot |
|
|
±5 |
% |
|
|
Output Capacitance |
|
3000 |
|
μF |
|
Protection Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
Input under voltage lock out |
Turn-on voltage threshold |
140 |
|
165 |
Vac |
|
Turn-off voltage threshold |
130 |
|
160 |
Vac |
|
|
Input over voltage protection |
Protect voltage |
290 |
|
310 |
Vac |
|
Recovery voltage |
285 |
|
300 |
Vac |
|
|
Output over voltage protection |
9V |
11 |
|
14 |
Vdc |
Hiccup,half load |
Output over load protection |
9Vmoden |
2.4 |
|
7 |
A |
Hiccup |
9V |
3.9 |
|
8 |
A |
Hiccup |
|
Short – Circuit Protection |
|
|
100 |
mΩ |
Hiccup |
General Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
MTBF |
100 |
|
|
KHrs |
Rated input, full load,25℃ |
Weight |
|
300 |
|
g |
|
Environmental Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
Operating temperature |
-25 |
|
+55 |
℃ |
|
Storage temperature |
-40 |
|
+85 |
℃ |
|
Relative humidity |
10 |
|
90 |
% |
|
Storage humidity |
10 |
|
95 |
% |
|
Safety Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
|
Isolation voltage |
Input to output |
1500 |
|
|
Vac |
10mA/1min, No arcing and breakdown |
Input to ground |
1500 |
|
|
Vac |
||
Output to ground |
500 |
|
|
Vdc |
10mA/1min, No arcing and breakdown |
|
Isolation resistance |
Input to output |
2 |
|
|
MΩ |
500Vdc/1min, normal atmospheric pressure, 90% humidity |
Leakage current |
Input to ground |
|
|
1.5 |
mA |
285Vac,normal condition |
|
|
1.5 |
mA |
285Vac,single fault |
Battery Management
Parameter |
Min |
Typ |
Max |
Units |
Notes |
Rated battery voltage |
|
9 |
|
V |
|
Charging voltage |
8.5 |
8.8 |
8.9 |
V |
|
Charging current |
0 |
|
0.15 |
A |
|
Battery under voltage protection |
6.5 |
7 |
7.5 |
V |
|
Notes:
+9V Li battery will automatically switch on when AC input failed. Battery will stop discharging when battery under voltage.
Signal and Switch
Item |
Min |
Typ |
Max |
Unit |
Notes |
|
AC/OK |
Input OK |
0 |
|
0.5 |
Vdc |
Battery loaded |
Input fail |
3.3 |
|
5.0 |
Vdc |
||
DC/OK |
+9V OK |
0 |
|
0.5 |
Vdc |
|
+9V fail |
3.3 |
|
5.0 |
Vdc |
||
+9V Remote control |
ON |
0 |
|
0.5 |
Vdc |
|
OFF |
2.5 |
|
5.0 |
Vdc |
External TTL signal to control +9V on/off |
Notes:
Test alarm and signal must load battery.
EMC Characteristics
Item |
Standards |
Conditions |
Notes |
|
CE |
EN55022 |
Class B |
Pass system test |
|
RE |
EN55022 |
Class B |
Pass system test |
|
Harmonic |
EN61000-3-2 |
C type lamps requirements |
Criterion B |
|
Voltage fluctuations and flicker |
EN61000-3-3 |
Class A equipments requirements |
Criterion B |
|
Surge |
EN61000-4-5 |
Differential mode ±2KV,common mode±4KV |
Criterion B |
|
DIP |
EN61000-4-11 EN55024 |
Voltage dip to 0%Ut,10ms |
Criterion B, test at phase 0, 90, 180 and 270 |
|
Voltage dip to 40%Ut, 20ms |
||||
Voltage dip to 70%Ut,50ms |
||||
ESD |
Air discharge |
EN61000-4-2 |
±8KV |
Criterion B |
Contact discharge |
EN61000-4-2 |
±4KV |
Criterion B |
Notes:
Criterion A: Normal performance during and after test.
Criterion B: Low-voltage protection or reset is not allowed. Temporary output voltage fluctuation ceases after disturbances ceases, and from which the EUT recovers its normal performance automatically. During the system test, output voltage fluctuation or reset is not allowed too.
Criterion C: Temporary loss of output is allowed, but the hardware can’t be damaged. The EUT recovers its normal performance automatically or operator intervention.
Criterion R: Loss of output which is not recoverable is allowed. The primary protective component (fuse) can be damaged. The EUT recovers its normal performance after replace the damaged component.
Environmental Qualification
Parameter |
Notes |
Vibration |
10-55Hz sweep, 1 min./sweep, 120 sweeps for 3 axis |
Mechanical Shock |
100g min, 2 drops in x and y axis, 1 drop in z axis |
Cold(in operation) |
IEC60068-2-1 Ad |
Damp heat |
IEC60068-2-67 Cy |
Temperature Cycling |
-40°C to 100°C, ramp 15°C/min., 500 cycles |
Power/Thermal Cycling |
Vin = min to max, full load, 100 cycles |
Design Marginality |
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load |
Life Test |
95% rated Vin and load, units at derating point, 1000 hours |
Solder ability |
IEC60068-2-20 |
Standards compliance
Standards |
Notes |
UL/cUL60950 |
|
EN60950 |
|
GB4943 |
|
Mechanical Outline
Length×width×heigth:129×98×38 (mm), 5.08×3.86×1.50(in),
Connector designations
Pin# |
Name |
Functions |
1 |
FG |
GND |
2 |
N |
AC input |
3 |
L |
AC input |
4 |
GND |
Signal GND |
5 |
9VOFF |
9V ON/OFF control signal |
6 |
DC/OK |
9V output OK signal |
7 |
AC/OK |
AC input OK signal |
8 |
BAT+ |
Battery output + |
9 |
GND |
Output GND |
10 |
9VMOD |
9VModne output + |
11 |
GND |
Output GND |
12 |
GND |
Output GND |
13 |
9V |
9V output + |